Material: Concrete
Condition: Unsecured Hollow
TPAS Code: H
Condition Type (AutoCAD Layer): Concrete_Unsecured
Severity Units: Not applicable
Ammount Units: Area in square feet
Description: Area of concrete that appears to have a void behind the intact surface, based on sounding with a mallet.