Material: Concrete
Condition: Joint Mortar Caulked Failed
TPAS Code: MorClkF
Condition Type (AutoCAD Layer): Concrete_Joint
Severity Units: Not applicable
Ammount Units: Length in lineal feet
Description: Joints in concrete or cast stone masonry where sealant has been applied over the mortar, and the sealant exhibits cracking, separation, total loss or other signs of deterioration.