Material: Terra Cotta
Condition: Joints Sealant Failed
TPAS Code: SlntF
Condition Type (AutoCAD Layer): TerraCotta_Joint
Severity Units: Not applicable
Ammount Units: Lineal feet of sealant failed
Description: Joints containing sealant, such as at flashing, in which the sealant exhibits cracking, separation, total loss or other signs of deterioration.

Image 1
Sealant failed in glazed terra cotta at caulked mortar joints
Image 3
Sealant failed in glazed terra cotta at flashing
Image 2
Sealant failed in glazed terra cotta at flashing
Image 4
Sealant failed in glazed terra cotta at caulked mortar joint