Brick Crack Single Unit:
- TPAS Code: C, AutoCAD Layer: Brick_Crack
- Severtity Units: Width in 1/16 inch increments, Amount Units: Length in lineal feet
- Description: A crack through a single unit.
-
Brick Coating Failed:
- TPAS Code: CtF, AutoCAD Layer: Brick_Coating
- Severtity Units: Not Applicable, Amount Units: Area in Square Feet
- Description: Coating on brick that exhibits deterioration such as blistering, peeling, wrinkling, crazing, checking, alligatoring, chalking, staining or discoloration.
-
Brick Coating Sound:
- TPAS Code: Ct, AutoCAD Layer: Brick_Coating
- Severtity Units: Not Applicable, Amount Units: Area in square feet
- Description: Coating on brick that exhibits no signs of deterioration.
-
Brick Crack Repair Sound:
- TPAS Code: CRpr, AutoCAD Layer: Brick_Crack
- Severtity Units: Not Applicable, Amount Units: Length in lineal feet
- Description: A crack or crack system that has been filled using elastomeric, cementitious or other repair material.
-
Brick Crack Repair Failed:
- TPAS Code: CRprF, AutoCAD Layer: Brick_Crack
- Severtity Units: Not Applicable, Amount Units: Length in lineal feet
- Description: A crack or crack system that has been filled using elastomeric, cementitious or other repair material in which the repair material exhibits signs of failure or deterioration.
-
Brick Crack System Joint:
- TPAS Code: CJ, AutoCAD Layer: Brick_Crack
- Severtity Units: Width in 1/16 inch increments, Amount Units: Length in lineal feet
- Description: A crack following the path of two or more connecting joints without any fractured masonry units.
-
Brick Crack System Unit:
- TPAS Code: CU, AutoCAD Layer: Brick_Crack
- Severtity Units: Width in 1/16 inch increments, Amount Units: Length in lineal feet
- Description: A crack through more than one masonry unit, but not following, joints.
-
Brick Crack System Unit and Joint:
- TPAS Code: CUJ, AutoCAD Layer: Brick_Crack
- Severtity Units: Width in 1/16 inch increments, Amount Units: Length in lineal feet
- Description: A crack following the path of two or more connecting joints and passing through one or more masonry units.
-
Brick Displacement Horizontal and Vertical:
- TPAS Code: HV, AutoCAD Layer: Brick_Displacement
- Severtity Units: Displacement in 1/8 inch increments, Amount Units: Area affected in square feet
- Description: Units shifted out of their as-built position in both a horizontal (left/right or forward/back) and vertical (up/down) directions.
-
Brick Displacement Horizontal:
- TPAS Code: Hor, AutoCAD Layer: Brick_Displacement
- Severtity Units: Displacement in 1/8 inch increments, Amount Units: Area affected in square feet
- Description: Units shifted out of their as-built position in a left/right or forward/back direction.
-
Brick Displacement Vertical:
- TPAS Code: Vrt, AutoCAD Layer: Brick_Displacement
- Severtity Units: Displacement in 1/8 inch increments, Amount Units: Area affected in square feet
- Description: Units shifted out of their as-built position in an up/down direction.
-
Brick Ferrous Element:
- TPAS Code: Fe, AutoCAD Layer: Brick_Embed
- Severtity Units: Not Applicable, Amount Units: Not Applicable
- Description: Steel or iron fixture embedded in masonry; examples include anchors, fasteners and pipes.
-
Brick Joint Mortar Caulked:
- TPAS Code: MorClk, AutoCAD Layer: Brick_Joint
- Severtity Units: Not Applicable, Amount Units: Not Applicable
- Description: Joints in brick masonry where sealant has been applied over the mortar.
-
Brick Joint Mortar Failed:
- TPAS Code: MorF, AutoCAD Layer: Brick_Joint
- Severtity Units: Percent of joints affected, Amount Units: Not Applicable
- Description: Joints that exhibit eroded, friable, cracked or otherwise deteriorated mortar.
-
Brick Joint Mortar Missing:
- TPAS Code: MorM, AutoCAD Layer: Brick_Joint
- Severtity Units: Not Applicable, Amount Units: Lineal feet of mortar missing
- Description: Joints that are empty of mortar.
-
Brick Joint Sealant Failed:
- TPAS Code: SlntF, AutoCAD Layer: Brick_Joint
- Severtity Units: Not Applicable, Amount Units: Lineal feet of sealant failed
- Description: Joints containing sealant, such as expansion or control joints, in which the sealant exhibits cracking, separation, total loss or other signs of deterioration.
-
Brick Lintel Pack Rust:
- TPAS Code: Pck, AutoCAD Layer: Brick_Lintel
- Severtity Units: Not Applicable, Amount Units: Not Applicable
- Description: Expansive rusting of lintels or relieving angles constructed of rolled steel.
-
Brick Lintel Surface Rust:
- TPAS Code: Srf, AutoCAD Layer: Brick_Lintel
- Severtity Units: Not Applicable, Amount Units: Not Applicable
- Description: Rusting steel lintel or relieving angle, which has not yet begun to delaminate or expand.
-
Brick Repair Patch Failed:
- TPAS Code: PF, AutoCAD Layer: Brick_Repair
- Severtity Units: Not Applicable, Amount Units: Size in square inches
- Description: A previous repair to a brick unit, typically made with cementitious material, that is cracked, separated, loose or otherwise deteriorated.
-
Brick Repair Patch Sound:
- TPAS Code: P, AutoCAD Layer: Brick_Repair
- Severtity Units: Not Applicable, Amount Units: Size in square inches
- Description: A previous repair to a brick unit, typically made with cementitious material, that exhibits no signs of failure.
-
Brick Repair Replacement:
- TPAS Code: Rpl, AutoCAD Layer: Brick_Repair
- Severtity Units: Not Applicable, Amount Units: Size in square inches
- Description: A repair made to brick masonry in which new brick unit(s) have been installed to replace an area of deterioration.
-
Brick Soiled Atmospheric:
- TPAS Code: Atm, AutoCAD Layer: Brick_SoilStain
- Severtity Units: Not Applicable, Amount Units: Area affected in square feet
- Description: Soiling from airborne pollutants.
-
Brick Soiled Biological:
- TPAS Code: Bio, AutoCAD Layer: Brick_SoilStain
- Severtity Units: Not Applicable, Amount Units: Area affected in square feet
- Description: Microbiological plant growth on the surface of masonry, such as algae, moss or lichen, or vascular plant growth, typically in gutters, cracks or on roofs.
-
Brick Soiled Bituminous:
- TPAS Code: Bit, AutoCAD Layer: Brick_SoilStain
- Severtity Units: Not Applicable, Amount Units: Area affected in square feet
- Description: Surface soiling on masonry from bituminous (hydrocarbon derived from crude oil) roofing or flashing materials.
-
Brick Soiled Cementitious:
- TPAS Code: Cem, AutoCAD Layer: Brick_SoilStain
- Severtity Units: Not Applicable, Amount Units: Area affected in square feet
- Description: Cementitious accretions and accumulations on the surface of masonry units resulting from repointing or patch repairs.
-
Brick Soiled Copper:
- TPAS Code: Cpr, AutoCAD Layer: Brick_SoilStain
- Severtity Units: Not Applicable, Amount Units: Area affected in square feet
- Description: Greenish copper-based stains, typically appearing as streaks below patinated copper elements.
-
Brick Soiled Efflorescence:
- TPAS Code: Eff, AutoCAD Layer: Brick_SoilStain
- Severtity Units: Not Applicable, Amount Units: Area affected in square feet
- Description: White, soft deposition on the surface of masonry due to evaporative precipitation of salts. When this process occurs below the surface of the masonry unit (subflorescence), it is revealed at areas of exfoliation or spalling.
-
Brick Soiled Guano:
- TPAS Code: Gua, AutoCAD Layer: Brick_SoilStain
- Severtity Units: Not Applicable, Amount Units: Area affected in square feet
- Description: Accumulation of bird droppings on the surface of masonry.
-
Brick Soiled Leached Salts:
- TPAS Code: Lch, AutoCAD Layer: Brick_SoilStain
- Severtity Units: Not Applicable, Amount Units: Area affected in square feet
- Description: Hard encrustations or deposits of salts on the surface of masonry, typically caused by salts being leached out of the mortar or back-up masonry through the effects of moisture.
-
Brick Soiled Paint:
- TPAS Code: Pnt, AutoCAD Layer: Brick_SoilStain
- Severtity Units: Not Applicable, Amount Units: area affected in square feet
- Description: Unintended drips or accumulations on the surface of masonry units resulting from painting work.
-
Brick Soiled Rust:
- TPAS Code: Rst, AutoCAD Layer: Brick_SoilStain
- Severtity Units: Not Applicable, Amount Units: Area Affected in square feet
- Description: Orange brown iron-based stains, typically appearing as streaks below steel or cast iron fasteners or elements.
-
Brick Spall Bonded:
- TPAS Code: B, AutoCAD Layer: Brick_Spall
- Severtity Units: Not Applicable, Amount Units: Size in square inches
- Description: Piece of material dislodged from a masonry unit by excessive stress that appears, based on visual inspection and sounding with a mallet where possible, to be solidly attached to the substrate, typically by means of mortar or adhesive.
-
Brick Spall Hazard:
- TPAS Code: Haz, AutoCAD Layer: Brick_Spall
- Severtity Units: Not Applicable, Amount Units: Size in square inches
- Description: Piece of material dislodged from a masonry unit by excessive stress that is loosely attached and presents an imminent life safety hazard, but which could not be safely removed during the investigation.
-
Brick Spall Incipient:
- TPAS Code: I, AutoCAD Layer: Brick_Spall
- Severtity Units: Not Applicable, Amount Units: Size in square inches
- Description: Partially formed spall that appears to be well attached.
-
Brick Spall Missing:
- TPAS Code: M, AutoCAD Layer: Brick_Spall
- Severtity Units: Not Applicable, Amount Units: Size in square inches
- Description: The location of a spall that is no longer in situ at the time of the investigation, with no steel evident.
-
Brick Spall Missing + Steel:
- TPAS Code: MS, AutoCAD Layer: Brick_Spall
- Severtity Units: Not Applicable, Amount Units: Size in square inches
- Description: The location of a spall that is no longer in situ at the time of the investigation and where there is steel evident, typically within the depression left by the missing spall.
-
Brick Spall Removed:
- TPAS Code: R, AutoCAD Layer: Brick_Spall
- Severtity Units: Not Applicable, Amount Units: Size in square inches
- Description: The location of a spall that was taken from the building at the time of the investigation, with no steel evident.
-
Brick Spall Removed + Steel:
- TPAS Code: RS, AutoCAD Layer: Brick_Spall
- Severtity Units: Not Applicable, Amount Units: Size in square inches
- Description: The location of a spall that was taken from the building at the time of the investigation and where there is steel evident, typically within the depression left by the missing spall.
-
Brick Surface Chipped:
- TPAS Code: Chp, AutoCAD Layer: Brick_SurfLoss
- Severtity Units: Depth of loss in 1/8 inch increments, Amount Units: Area affecrted in square feet
- Description: Shallow loss of material, typically at the edges of the masonry unit.
-
Brick Surface Eroded:
- TPAS Code: Erd, AutoCAD Layer: Brick_SurfLoss
- Severtity Units: Depth of loss in 1/8 inch increments, Amount Units: Area affected in square feet
- Description: Loss of material at the surface of the masonry unit, typically due to scouring by wind or rain.
-
Brick Surface Face Spall:
- TPAS Code: Fce, AutoCAD Layer: Brick_SurfLoss
- Severtity Units: Depth of loss in 1/8 inch increments, Amount Units: Area affected in square feet
- Description: Loss of outer surface of masonry unit in layers.
-
Brick Surface Friable:
- TPAS Code: Fri, AutoCAD Layer: Brick_SurfLoss
- Severtity Units: Depth of loss in 1/8 inch increments, Amount Units: Area affected in square feet
- Description: Loss of cohesion within masonry unit, resulting in a powdery texture.
-
Brick Unsecured Hazardous:
- TPAS Code: Haz, AutoCAD Layer: Brick_Unsecured
- Severtity Units: Not Applicable, Amount Units: Area in square feet
- Description: Area of masonry that has lost its construction integrity and presents a life safety hazard.
-
Brick Unsecured Hollow:
- TPAS Code: H, AutoCAD Layer: Brick_Unsecured
- Severtity Units: Not Applicable, Amount Units: Area in square feet
- Description: Area of masonry that appears to have a void behind the intact surface or face brick, based on sounding with a mallet.
-
Brick Unsecured Loose:
- TPAS Code: L, AutoCAD Layer: Brick_Unsecured
- Severtity Units: Not Applicable, Amount Units: Area in square feet
- Description: Area of masonry that can be moved by hand or when sounded with a mallet due to a loss of its construction integrity, but which is not removed during the investigation.
-
Brick Unsecured Missing:
- TPAS Code: M, AutoCAD Layer: Brick_Unsecured
- Severtity Units: Not Applicable, Amount Units: Area in square feet
- Description: Area of masonry where a void is visible at the surface due to missing brick unit(s).
-
Brick Unsecured Removed:
- TPAS Code: R, AutoCAD Layer: Brick_Unsecured
- Severtity Units: Not Applicable, Amount Units: Area in square feet
- Description: Area of masonry where a brick unit(s) was removed at the time of the investigation.
-
Concrete Coating Sound:
- TPAS Code: Ct, AutoCAD Layer: Concrete_Coating
- Severtity Units: Not Applicable, Amount Units: Area in square feet
- Description: Coating on concrete that exhibits no signs of deterioration.
-
Concrete Coating Failed:
- TPAS Code: CtF, AutoCAD Layer: Concrete_Coating
- Severtity Units: Not Applicable, Amount Units: Area in square feet
- Description: Coating on concrete that exhibits deterioration such as blistering, peeling, wrinkling, crazing, checking, alligatoring, chalking, staining or discoloration.
-
Concrete Crack Single Unit:
- TPAS Code: C, AutoCAD Layer: Concrete_Crack
- Severtity Units: Crack Width in 1/16 inch increments, Amount Units: Length in lineal feet
- Description: A crack visible at the surface of the concrete or through a single cast unit.
-
Concrete Crack Repair Sound:
- TPAS Code: CRpr, AutoCAD Layer: Concrete_Crack
- Severtity Units: Not applicable, Amount Units: Length in lineal feet
- Description: A crack or crack system that has been filled using elastomeric, cementitious or other repair material.
-
Concrete Crack Repair Failed:
- TPAS Code: CRprF, AutoCAD Layer: Conc Crk Rpr Failed
- Severtity Units: Not applicable, Amount Units: Length in lineal feet
- Description: A crack or crack system that has been filled using elastomeric, cementitious or other repair material in which the repair material exhibits signs of failure or deterioration.
-
Concrete Crazing:
- TPAS Code: Crz, AutoCAD Layer: Concrete_Crack
- Severtity Units: Width in 1/16 inch increments, Amount Units: Area affected in square feet
- Description: Small cracks, typically hairline in width and random in pattern, at the concrete surface.
-
Concrete Crack System Joint:
- TPAS Code: CJ, AutoCAD Layer: Concrete_Crack
- Severtity Units: Width in 1/16 inch increments, Amount Units: Lineal feet of crack
- Description: A crack following the path of two or more connecting joints without any fractured units.
-
Concrete Crack System Unit:
- TPAS Code: CU, AutoCAD Layer: Concrete_Crack
- Severtity Units: Width in 1/16 inch increments, Amount Units: Lineal feet of crack
- Description: A crack through more than one unit, crossing, but not following, joints.
-
Concrete Crack System Unit and Joint:
- TPAS Code: CUJ, AutoCAD Layer: Concrete_Crack
- Severtity Units: Width in 1/16 inch increments, Amount Units: Lineal feet of crack
- Description: A crack following the path of two or more connecting joints and passing through one or more units.
-
Concrete Displacement Horizontal:
- TPAS Code: Hor, AutoCAD Layer: Concrete_Displ
- Severtity Units: Displacement in 1/8 inch increments, Amount Units: Not applicable
- Description: Shift out of the as-built position in a left/right or forward/back direction.
-
Concrete Displacement Vertical:
- TPAS Code: Vrt, AutoCAD Layer: Concrete_Displ
- Severtity Units: Displacement in 1/8 inch increments, Amount Units: Not applicable
- Description: Shift out of the as-built position in an up/down direction.
-
Concrete Displacement Horizontal and Vertical:
- TPAS Code: HV, AutoCAD Layer: Concrete_Displ
- Severtity Units: Displacement in 1/8 inch increments, Amount Units: Not applicable
- Description: Shift out of the as-built position in both horizontal (left/right or forward/back) and vertical (up/down) directions.
-
Concrete Ferrous Element:
- TPAS Code: Fe, AutoCAD Layer: Concrete_Embed
- Severtity Units: Not applicable, Amount Units: Not applicable
- Description: Steel or iron fixture embedded in concrete and visible at the surface; examples include anchors, fasteners and pipes.
-
Concrete Joints Mortar Caulked:
- TPAS Code: MorClk, AutoCAD Layer: Concrete_Joint
- Severtity Units: Not applicable, Amount Units: Not applicable
- Description: Joints in concrete where sealant has been applied over the mortar.
-
Concrete Joints Mortar Failed:
- TPAS Code: MorF, AutoCAD Layer: Concrete_Joint
- Severtity Units: Percent of joints affected, Amount Units: Not applicable
- Description: Joints that exhibit eroded, friable, cracked or otherwise deteriorated mortar.
-
Concrete Joints Mortar Missing:
- TPAS Code: MorM, AutoCAD Layer: Concrete_Joint
- Severtity Units: Not applicable, Amount Units: Lineal feet of mortar missing
- Description: Joints that are empty of mortar.
-
Concrete Joints Sealant Failed:
- TPAS Code: SlntF, AutoCAD Layer: Concrete_Joint
- Severtity Units: Not applicable, Amount Units: Length in lineal feet
- Description: Joints containing sealant, such as expansion or control joints, in which the sealant exhibits cracking, separation, total loss or other signs of deterioration.
-
Concrete Repair Patch Failed:
- TPAS Code: PF, AutoCAD Layer: Concrete_Repair
- Severtity Units: Not applicable, Amount Units: Size in square inches
- Description: A previous repair to a concrete, typically made with cementitious material, that is cracked, separated, loose or otherwise deteriorated.
-
Concrete Repair Patch Sound:
- TPAS Code: P, AutoCAD Layer: Concrete_Repair
- Severtity Units: Not applicable, Amount Units: Size in square inches
- Description: A previous repair to concrete, typically made with cementitious material, that exhibits no signs of failure., 66_Photo1, Patch repair in concrete panel
-
Concrete Repair Replacement:
- TPAS Code: Rpl, AutoCAD Layer: Concrete_Repair
- Severtity Units: Not applicable, Amount Units: Number of replacement units
- Description: A repair made to concrete in which a new pre-cast unit or section of cast-in-place concrete has been installed to replace an area of deterioration.
-
Concrete Soiled Atmospheric:
- TPAS Code: Atm, AutoCAD Layer: Concrete_SoilStain
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Soiling from airborne pollutants.
-
Concrete Soiled Biological:
- TPAS Code: Bio, AutoCAD Layer: Concrete_SoilStain
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Microbiological plant growth on the surface of masonry, such as algae, moss or lichen, or vascular plant growth, typically in gutters, cracks or on roofs.
-
Concrete Soiled Bituminous:
- TPAS Code: Bit, AutoCAD Layer: Concrete_SoilStain
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Surface soiling on concrete from bituminous (hydrocarbon derived from crude oil) roofing or flashing materials.
-
Concrete Soiled Copper:
- TPAS Code: Cpr, AutoCAD Layer: Concrete_SoilStain
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Greenish copper-based stains, typically appearing as streaks below patinated copper elements.
-
Concrete Soiled Efflorescence:
- TPAS Code: Eff, AutoCAD Layer: Concrete_SoilStain
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: White, soft deposition on the surface of concrete due to evaporative precipitation of salts. When this process occurs below the surface of the concrete (subflorescence), it is revealed at areas of exfoliation or spalling.
-
Concrete Soiled Guano:
- TPAS Code: Gua, AutoCAD Layer: Concrete_SoilStain
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Accumulation of bird droppings on the surface of concrete.
-
Concrete Leached Salts:
- TPAS Code: Lch, AutoCAD Layer: Concrete_SoilStain
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Hard encrustations or deposits of salts on the surface of concrete, typically caused by salts being leached out of the mortar or back-up masonry through the effects of moisture.
-
Concrete Soiled Paint:
- TPAS Code: Pnt, AutoCAD Layer: Concrete_SoilStain
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Unintended drips or accumulations on the surface of concrete resulting from painting work.
-
Concrete Soiled Rust:
- TPAS Code: Rst, AutoCAD Layer: Concrete_SoilStaint
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Orange brown iron-based stains, typically appearing as streaks below steel or cast iron fasteners or elements.
-
Concrete Spall Bonded:
- TPAS Code: B, AutoCAD Layer: Concrete_Spall
- Severtity Units: Not applicable, Amount Units: Size in square inches
- Description: Piece of material dislodged from concrete by excessive stress that appears, based on visual inspection and sounding with a mallet where possible, to be solidly attached to the substrate, typically by means of mortar or adhesive.
-
Concrete Spall Incipient:
- TPAS Code: I, AutoCAD Layer: Concrete_Spall
- Severtity Units: Not applicable, Amount Units: Size in square inches
- Description: Partially formed spall that appears to be well attached.
-
Concrete Spall Hazard:
- TPAS Code: Haz, AutoCAD Layer: Concrete_Spall
- Severtity Units: Not applicable, Amount Units: Size in square inches
- Description: Piece of material dislodged from concrete by excessive stress that is loosely attached and presents an imminent life safety hazard, but which could not be safely removed during the investigation.
-
Concrete Spall Missing:
- TPAS Code: M, AutoCAD Layer: Concrete_Spall
- Severtity Units: Not applicable, Amount Units: Size in square inches
- Description: The location of a spall that is no longer in situ at the time of the investigation, with no steel evident.
-
Concrete Spall Missing + Steel:
- TPAS Code: MS, AutoCAD Layer: Concrete_Spall
- Severtity Units: Not applicable, Amount Units: Size in square inches
- Description: The location of a spall that is no longer in situ at the time of the investigation and where there is steel evident, typically within the depression left by the missing spall.
-
Concrete Spall Removed:
- TPAS Code: R, AutoCAD Layer: Concrete_Spall
- Severtity Units: Not applicable, Amount Units: Size in square inches
- Description: The location of a spall that was taken from the building at the time of the investigation, with no steel evident.
-
Concrete Spall Removed + Steel:
- TPAS Code: RS, AutoCAD Layer: Concrete_Spall
- Severtity Units: Not applicable, Amount Units: Size in square inches
- Description: The location of a spall that was taken from the building at the time of the investigation and where there is steel evident, typically within the depression left by the missing spall.
-
Concrete Surface Chipped:
- TPAS Code: Chp, AutoCAD Layer: Concrete_SurfLoss
- Severtity Units: Depth of loss in 1/8 inch increments, Amount Units: Area affected in square feet
- Description: Shallow loss of material, typically at the edges or corners.
-
Concrete Surface Eroded:
- TPAS Code: Er, AutoCAD Layer: Concrete_SurfLoss
- Severtity Units: Depth of loss in 1/8 inch increments, Amount Units: Area affected in square feet
- Description: Loss of material at the surface of the concrete, typically due to scouring by wind or rain.
-
Concrete Surface Exfoliated:
- TPAS Code: Exf, AutoCAD Layer: Concrete_SurfLoss
- Severtity Units: Depth of loss in 1/8 inch increments, Amount Units: Area affected in square feet
- Description: Loss of outer surface of concrete in layers.
-
Concrete Surface Friable:
- TPAS Code: Fri, AutoCAD Layer: Concrete_SurfLoss
- Severtity Units: Depth of loss in 1/8 inch increments, Amount Units: Area affected in square feet
- Description: Loss of cohesion within concrete, resulting in a powdery texture.
-
Concrete Unsecured Hazardous:
- TPAS Code: Haz, AutoCAD Layer: Concrete_Unsecured
- Severtity Units: Not applicable, Amount Units: Area in square feet
- Description: Area of concrete that has lost its construction integrity and presents a life safety hazard.
-
Concrete Unsecured Hollow:
- TPAS Code: H, AutoCAD Layer: Concrete_Unsecured
- Severtity Units: Not applicable, Amount Units: Area in square feet
- Description: Area of concrete that appears to have a void behind the intact surface, based on sounding with a mallet.
-
Concrete Unsecured Loose:
- TPAS Code: L, AutoCAD Layer: Concrete_Unsecured
- Severtity Units: Not applicable, Amount Units: Area in square feet
- Description: Area of concrete that can be moved by hand or when sounded with a mallet due to a loss its construction integrity.
-
Concrete Unsecured Missing:
- TPAS Code: M, AutoCAD Layer: Concrete_Unsecured
- Severtity Units: Not applicable, Amount Units: Area in square feet
- Description: Area of concrete where a void is visible at the surface due to missing material.
-
Concrete Unsecured Removed:
- TPAS Code: R, AutoCAD Layer: Concrete_Unsecured
- Severtity Units: Not applicable, Amount Units: Area is square feet
- Description: Area of concrete where material was removed at the time of the investigation.
-
Stone Coating Failed:
- TPAS Code: CtF, AutoCAD Layer: Stone_Coating
- Severtity Units: Not applicable, Amount Units: Area in square feet
- Description: Coating on stone that exhibits deterioration such as blistering, peeling, wrinkling, crazing, checking, alligatoring, chalking, staining or discoloration.
-
Stone Coating Sound:
- TPAS Code: Ct, AutoCAD Layer: Stone_Coating
- Severtity Units: Not applicable, Amount Units: Area in square feet
- Description: Coating on stone that exhibits no signs of deterioration.
-
Stone Crack Single Unit:
- TPAS Code: C, AutoCAD Layer: Stone_Crack
- Severtity Units: Width in 1/16 inch increments, Amount Units: Length in lineal feet
- Description: A crack through a single unit.
-
Stone Crack Repair Sound:
- TPAS Code: CRpr, AutoCAD Layer: Stone_Crack
- Severtity Units: Not applicable, Amount Units: Length in lineal feet
- Description: A crack or crack system that has been filled using elastomeric, cementitious or other repair material.
-
Stone Crack Repair Failed:
- TPAS Code: CRprF, AutoCAD Layer: Stone_Crack
- Severtity Units: Not applicable, Amount Units: Length in lineal feet
- Description: A crack or crack system that has been filled using elastomeric, cementitous or other repair material in which the repair material exhibits signs of failure or deterioration.
-
Stone Crack System Joint:
- TPAS Code: CJ, AutoCAD Layer: Stone_Crack
- Severtity Units: Width in 1/16 inch increments, Amount Units: Length in lineal feet
- Description: A crack following the path of two or more connecting joints without any fractured masonry units.
-
Stone Crack System Unit:
- TPAS Code: CU, AutoCAD Layer: Stone_Crack
- Severtity Units: Width in 1/16 inch increments, Amount Units: Length in lineal feet
- Description: A crack through more than one masonry unit, crossing, but not following, joints.
-
Stone Crack System Unit and Joint:
- TPAS Code: CUJ, AutoCAD Layer: Stone_Crack
- Severtity Units: Width in 1/16 inch increments, Amount Units: Length in lineal feet
- Description: A crack following the path of two or more connecting joints and passing through one or more masonry units.
-
Stone Displacement Horizontal:
- TPAS Code: Hor, AutoCAD Layer: Stone_Displ
- Severtity Units: Displacement in 1/8 inch increments, Amount Units: Number of displaced units
- Description: Shift out of the as-built position in a left/right or forward/back direction.
-
Stone Displacement Vertical:
- TPAS Code: Vrt, AutoCAD Layer: Stone_Displ
- Severtity Units: Displacement in 1/8 inch increments, Amount Units: Number of displaced units
- Description: Shift out of the as-built position in an up/down direction.
-
Stone Displacement Horizontal and Vertical:
- TPAS Code: HV, AutoCAD Layer: Stone_Displ
- Severtity Units: Displacement in 1/8 inch increments, Amount Units: Number of displaced units
- Description: Shift out of the as-built position in both horizontal (left/right or forward/back) and vertical (up/down) directions.
-
Stone Ferrous Element:
- TPAS Code: Fe, AutoCAD Layer: Stone_Embed
- Severtity Units: Not applicable, Amount Units: Not applicable
- Description: Steel or iron fixture embedded in masonry; examples include anchors, fasteners and pipes.
-
Stone Joints Mortar Caulked:
- TPAS Code: MorClk, AutoCAD Layer: Stone_Joints
- Severtity Units: Not applicable, Amount Units: Not applicable
- Description: Joints in stone masonry where sealant has been applied over the mortar.
-
Stone Joints Mortar Failed:
- TPAS Code: MorF, AutoCAD Layer: Stone_Joints
- Severtity Units: Percent of joints affected, Amount Units: Not applicable
- Description: Joints that exhibit eroded, friable, cracked or otherwise deteriorated mortar.
-
Stone Joints Mortar Missing:
- TPAS Code: MorM, AutoCAD Layer: Stone_Joints
- Severtity Units: Not applicable, Amount Units: Lineal feet of mortar missing
- Description: Joints that are empty of mortar
-
Stone Joints Sealant Failed:
- TPAS Code: SlntF, AutoCAD Layer: Stone_Joints
- Severtity Units: Not applicable, Amount Units: Lineal feet of sealant failed
- Description: Joints containing sealant, such as expansion or control joints, in which the sealant exhibits cracking, separation, total loss or other signs of deterioration.
-
Stone Lintel Pack Rust:
- TPAS Code: Pck, AutoCAD Layer: Stone_Lintel
- Severtity Units: Not applicable, Amount Units: Not applicable
- Description: Expansive rusting of lintels or relieving angles constructed of rolled steel.
-
Stone Lintel Surface Rust:
- TPAS Code: Srf, AutoCAD Layer: Stone_Lintel
- Severtity Units: Not applicable, Amount Units: Not applicable
- Description: Rusting steel lintel or relieving angle, which has not yet begun to delaminate or expand.
-
Stone Repair Dutchman Failed:
- TPAS Code: DF, AutoCAD Layer: Stone_Repair
- Severtity Units: Not applicable, Amount Units: Size in square inches
- Description: A previous repair to a stone unit, made by installing a natural stone infill piece at an area of deterioration, that is cracked, separated, loose or otherwise failing.
-
Stone Repair Dutchman Sound:
- TPAS Code: D, AutoCAD Layer: Stone_Repair
- Severtity Units: Not applicable, Amount Units: Size in square inches
- Description: A previous repair to a stone unit, made by installing a natural stone infill piece at an area of deterioration, that exhibits no signs of failure.
-
Stone Repair Patch Failed:
- TPAS Code: PF, AutoCAD Layer: Stone_Repair
- Severtity Units: Not applicable, Amount Units: Size in square inches
- Description: A previous repair to a stone unit, typically made with cementitious material, that is cracked, separated, loose or otherwise deteriorated.
-
Stone Repair Patch Sound:
- TPAS Code: P, AutoCAD Layer: Stone_Repair
- Severtity Units: Not applicable, Amount Units: Size in square inches
- Description: A previous repair to a stone unit, typically made with cementitious material, that exhibits no signs of failure.
-
Stone Repair Replacement:
- TPAS Code: Rpl, AutoCAD Layer: Stone_Repair
- Severtity Units: Not applicable, Amount Units: Number of replacement units
- Description: A repair made to stone masonry in which new stone unit(s) have been installed to replace an area of deterioration.
-
Stone Soiled Atmospheric:
- TPAS Code: Atm, AutoCAD Layer: Stone_SoilStain
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Soiling from airborne pollutants.
-
Stone Soiled Biological:
- TPAS Code: Bio, AutoCAD Layer: Stone_SoilStain
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Microbiological plant growth on the surface of masonry, such as algae, moss or lichen, or vascular plant growth, typically in gutters, cracks or on roofs.
-
Stone Soiled Bituminous:
- TPAS Code: Bit, AutoCAD Layer: Stone_SoilStain
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Surface soiling on stone from bituminous (hydrocarbon derived from crude oil) roofing or flashing materials.
-
Stone Soiled Copper:
- TPAS Code: Cpr, AutoCAD Layer: Stone_SoilStain
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Greenish copper-based stains, typically appearing as streaks below patinated copper elements.
-
Stone Soiled Efflorescence:
- TPAS Code: Eff, AutoCAD Layer: Stone_SoilStain
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: White, soft deposition on the surface of masonry due to evaporative precipitation of salts. When this process occurs below the surface of the stone (subflorescence), it is revealed at areas of exfoliation or spalling.
-
Stone Soiled Black Crusts:
- TPAS Code: Blk, AutoCAD Layer: Stone_SoilStain
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Accumulation of insoluble gypsum formed by the reaction of particulate pollutants with the stone and darkened by atmospheric soiling.
-
Stone Soiled Cementitous:
- TPAS Code: Cem, AutoCAD Layer: Stone_SoilStain
- Severtity Units: Not applicable, Amount Units: area affected in square feet
- Description: Cementitious accretions and accumulations on the surface on the surface of masonry units resulting from repointing or patch repairs.
-
Stone Soiled Guano:
- TPAS Code: Gua, AutoCAD Layer: Stone_SoilStain
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Accumulation of bird droppings on the surface of masonry.
-
Stone Soiled Leached Salts:
- TPAS Code: Lch, AutoCAD Layer: Stone_SoilStain
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Hard encrustations or deposits of salts on the surface of masonry, typically caused by salts being leached out of the mortar or back-up masonry through the effects of moisture.
-
Stone Soiled Paint:
- TPAS Code: Pnt, AutoCAD Layer: Stone_SoilStain
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Unintended drips or accumulations on the surface of masonry units resulting from painting work.
-
Stone Soiled Rust:
- TPAS Code: Rst, AutoCAD Layer: Stone_SoilStain
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Orange brown iron-based stains, typically appearing as streaks below steel or cast iron fasteners or elements.
-
Stone Spall Bonded:
- TPAS Code: B, AutoCAD Layer: Stone_Spall
- Severtity Units: Not applicable, Amount Units: Size in square inches
- Description: Piece of material dislodged from masonry by excessive stress that appears, based on visual inspection and sounding with a mallet where possible, to be solidly attached to the substrate, typically by means of mortar or adhesive.
-
Stone Spall Hazard:
- TPAS Code: Haz, AutoCAD Layer: Stone_Spall
- Severtity Units: Not applicable, Amount Units: Size in square inches
- Description: Piece of material dislodged from masonry by excessive stress that is loosely attached and presents an imminent life safety hazard, but which could not be safely removed during the investigation.
-
Stone Spall Incipient:
- TPAS Code: I, AutoCAD Layer: Stone_Spall
- Severtity Units: Not applicable, Amount Units: Size in square inches
- Description: Partially formed spall that appears to be well attached.
-
Stone Spall Missing:
- TPAS Code: M, AutoCAD Layer: Stone_Spall
- Severtity Units: Not applicable, Amount Units: Size in square inches
- Description: The location of a spall that is no longer in situ at the time of the investigation, with no steel evident.
-
Stone Spall Missing + Steel:
- TPAS Code: MS, AutoCAD Layer: Stone_Spall
- Severtity Units: Not applicable, Amount Units: Size in square inches
- Description: The location of a spall that is no longer in situ at the time of the investigation and where there is steel evident, typically within the depression left by the missing spall.
-
Stone Spall Removed:
- TPAS Code: R, AutoCAD Layer: Stone_Spall
- Severtity Units: Not applicable, Amount Units: Size in square inches
- Description: The location of a spall that was taken from the building at the time of the investigation, with no steel evident.
-
Stone Spall Removed + Steel:
- TPAS Code: RS, AutoCAD Layer: Stone_Spall
- Severtity Units: Not applicable, Amount Units: Size in sq. in.
- Description: The location of a spall that was taken from the building at the time of the investigation and where there is steel evident, typically within the depression left by the missing spall.
-
Stone Surface Chipped:
- TPAS Code: Chp, AutoCAD Layer: Stone_SurfLoss
- Severtity Units: Depth of loss in 1/8 inch increments, Amount Units: Area affected in square feet
- Description: Shallow loss of material, typically at the edges of a masonry unit.
-
Stone Surface Delaminated:
- TPAS Code: Dlm, AutoCAD Layer: Stone_SurfLoss
- Severtity Units: Depth of loss in 1/8 inch increments, Amount Units: Area affected in square feet
- Description: Separation of layers along natural bedding planes, resulting in loss of material at the outer surface of the unit or voids within the unit.
-
Stone Surface Eroded:
- TPAS Code: Er, AutoCAD Layer: Stone_SurfLoss
- Severtity Units: Depth of loss in 1/8 inch increments, Amount Units: Area affected in square feet
- Description: Loss of material at the surface of the masonry, typically due to scouring by wind or rain.
-
Stone Surface Exfoliated:
- TPAS Code: Exf, AutoCAD Layer: Stone_SurfLoss
- Severtity Units: Depth of loss in 1/8 inch increments, Amount Units: Area affected in square feet
- Description: Loss of outer surface of a masonry unit in layers.
-
Stone Surface Friable:
- TPAS Code: Fri, AutoCAD Layer: Stone_SurfLoss
- Severtity Units: Depth of loss in 1/8 inch increments, Amount Units: Area affected in square feet
- Description: Loss of cohesion within a masonry unit, resulting in a powdery texture.
-
Stone Unsecured Hazardous:
- TPAS Code: Haz, AutoCAD Layer: Stone_Unsecured
- Severtity Units: Not applicable, Amount Units: Area in square feet
- Description: Area of masonry that has lost its construction integrity and presents a life safety hazard.
-
Stone Unsecured Hollow:
- TPAS Code: H, AutoCAD Layer: Stone_Unsecured
- Severtity Units: Not applicable, Amount Units: Area in square feet
- Description: Area of masonry that appears to have a void behind the intact surface, based on sounding with a mallet.
-
Stone Unsecured Loose:
- TPAS Code: L, AutoCAD Layer: Stone_Unsecured
- Severtity Units: Not applicable, Amount Units: Area in square feet
- Description: Area of masonry that can be moved by hand or when sounded with a mallet due to a loss its construction integrity.
-
Stone Unsecured Missing:
- TPAS Code: M, AutoCAD Layer: Stone_Unsecured
- Severtity Units: Not applicable, Amount Units: Area in square inches
- Description: Area of masonry where a void is visible at the surface due to missing material.
-
Stone Unsecured Removed:
- TPAS Code: R, AutoCAD Layer: Stone_Unsecured
- Severtity Units: Not applicable, Amount Units: Area in square feet
- Description: Area of masonry where material was removed at the time of the investigation.
-
Terra Cotta Coating Sound:
- TPAS Code: Ct, AutoCAD Layer: TerraCotta_Coating
- Severtity Units: Not applicable, Amount Units: Area in square inches
- Description: Coating on terra cotta that exhibits no sign of deterioration.
-
Terra Cotta Coating Failed:
- TPAS Code: CtF, AutoCAD Layer: TerraCotta_Coating
- Severtity Units: Not applicable, Amount Units: Area in square inches
- Description: Coating on terra cotta that exhibits deterioration such as blistering, peeling, wrinkling, crazing, checking, alligatoring, chalking, staining or discoloration.
-
Terra Cotta Crack Single Unit:
- TPAS Code: C, AutoCAD Layer: TerraCotta_Crack
- Severtity Units: Width in 1/16 inch increments, Amount Units: Length in lineal feet
- Description: A crack through a single unit.
-
Terra Cotta Crack Repair Sound:
- TPAS Code: CRpr, AutoCAD Layer: TerraCotta_Crack
- Severtity Units: Not Applicable, Amount Units: Length in lineal feet
- Description: A crack or crack system that has been filled using elastomeric, cementitious or other repair material.
-
Terra Cotta Crack Repair Failed:
- TPAS Code: CRprF, AutoCAD Layer: TerraCotta_Crack
- Severtity Units: Not applicable, Amount Units: Length in lineal feet
- Description: A crack or crack system that has been filled using elastomeric, cementitious or other repair material in which the repair material exhibits signs of failure or deterioration.
-
Terra Cotta Crazed:
- TPAS Code: Crz, AutoCAD Layer: TerraCotta_Crack
- Severtity Units: Not applicable, Amount Units: Area in square feet
- Description: Small cracks, typically hairline in width and random in pattern, in the glaze of a terra cotta unit.
-
Terra Cotta Crack System Joint:
- TPAS Code: CJ, AutoCAD Layer: TerraCotta_Crack
- Severtity Units: Width in 1/16 inch increments, Amount Units: Lineal feet of crack
- Description: A crack following the path of two or more connecting joints without any fractured terra cotta units.
-
Terra Cotta Crack System Unit:
- TPAS Code: CU, AutoCAD Layer: TerraCotta_Crack
- Severtity Units: Width in 1/16 inch increments, Amount Units: Lineal feet of crack
- Description: A crack through more than one terra cotta unit, crossing, but not following joints.
-
Terra Cotta Crack System Unit and Joint:
- TPAS Code: CUJ, AutoCAD Layer: TerraCotta_Crack
- Severtity Units: Width in 1/16 inch increments, Amount Units: Lineal feet of crack
- Description: A crack following the path of two or more connecting joints and passing through one or more masonry units.
-
Terra Cotta Displacement Horizontal:
- TPAS Code: Hor, AutoCAD Layer: TerraCotta_Displ
- Severtity Units: Displacement in 1/8 inch increments, Amount Units: Number of units displaced
- Description: Unit(s) shifted out of their as built position in a horizontal (left/right or forward/back) direction.
-
Terra Cotta Displacement Vertical:
- TPAS Code: Vrt, AutoCAD Layer: TerraCotta_Displ
- Severtity Units: Displacement in 1/8 inch increments, Amount Units: Number of units displaced
- Description: Unit(s) shifted out of their as built position in a vertical (up/down) direction.
-
Terra Cotta Displacement Horizontal and Vertical:
- TPAS Code: HV, AutoCAD Layer: TerraCotta_Displ
- Severtity Units: Displacement in 1/8 inch increments, Amount Units: Number of units displaced
- Description: Unit(s) shifted out of their as built position in both a horizontal (left/right or forward/back) and vertical (up/down) direction.
-
Terra Cotta Ferrous Element:
- TPAS Code: Fe, AutoCAD Layer: TerraCotta_Embed
- Severtity Units: Not applicable, Amount Units: Not applicable
- Description: Steel or iron fixture embedded in terra cotta; examples include anchors, fasteners and pipes.
-
Terra Cotta Joints Mortar Caulked:
- TPAS Code: MorClk, AutoCAD Layer: TerraCotta_Joint
- Severtity Units: Not applicable, Amount Units: Not applicable
- Description: Joints in terra cotta masonry where sealant has been applied over the mortar.
-
Terra Cotta Joints Mortar Failed:
- TPAS Code: MorF, AutoCAD Layer: TerraCotta_Joint
- Severtity Units: Percent of joints affected, Amount Units: Not applicable
- Description: Joints that exhibit eroded, friable, cracked or otherwise deteriorated mortar.
-
Terra Cotta Joints Mortar Missing:
- TPAS Code: MorM, AutoCAD Layer: TerraCotta_Joint
- Severtity Units: Not applicable, Amount Units: Lineal feet of mortar missing
- Description: Joints that are empty of mortar.
-
Terra Cotta Joints Sealant Failed:
- TPAS Code: SlntF, AutoCAD Layer: TerraCotta_Joint
- Severtity Units: Not applicable, Amount Units: Lineal feet of sealant failed
- Description: Joints containing sealant, such as at flashing, in which the sealant exhibits cracking, separation, total loss or other signs of deterioration.
-
Terra Cotta Lintel Pack Rust:
- TPAS Code: Pck, AutoCAD Layer: TerraCotta_Lintel
- Severtity Units: Not applicable, Amount Units: Not applicable
- Description: Expansive rusting of lintels or relieving angles constructed of rolled steel.
-
Terra Cotta Lintel Surface Rust:
- TPAS Code: Srf, AutoCAD Layer: TerraCotta_Lintel
- Severtity Units: Not applicable, Amount Units: Not applicable
- Description: Rusting steel lintel or relieving angle, which has not yet begun to delaminate or expand.
-
Terra Cotta Repair Patch Sound:
- TPAS Code: P, AutoCAD Layer: TerraCotta_Repair
- Severtity Units: Not applicable, Amount Units: Size in square inches
- Description: A previous repair to a terra cotta unit, typically made with cementitious material, that exhibits no signs of failure.
-
Terra Cotta Repair Patch Failed:
- TPAS Code: PF, AutoCAD Layer: TerraCotta_Repair
- Severtity Units: Not applicable, Amount Units: Size in square inches
- Description: A previous repair to a terra cotta unit, typically made with cementitious material, that is cracked, separated, loose or otherwise deteriorated.
-
Terra Cotta Repair Replacement:
- TPAS Code: Rpl, AutoCAD Layer: TerraCotta_Repair
- Severtity Units: Not applicable, Amount Units: Number of replacement units
- Description: A repair made to terra cotta masonry in which a new terra cotta or material intended to simulate terra cotta has been installed to replace a deteriorated unit.
-
Terra Cotta Soiled Atmospheric:
- TPAS Code: Atm, AutoCAD Layer: TerraCotta_SoilStain
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Soiling from airborne pollutants.
-
Terra Cotta Soiled Biological:
- TPAS Code: Bio, AutoCAD Layer: TerraCotta_SoilStain
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Microbiological plant growth on the surface of masonry, such as algae, moss or lichen, or vascular plant growth, typically in gutters, cracks or on roofs.
-
Terra Cotta Soiled Bituminous:
- TPAS Code: Bit, AutoCAD Layer: TerraCotta_SoilStain
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Surface soiling on masonry from bituminous (hydrocarbon derived from crude oil) roofing or flashing materials.
-
Terra Cotta Soiled Cementitious:
- TPAS Code: Cem, AutoCAD Layer: TerraCotta_SoilStain
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Cementitious accretions or accumulations on the surface of masonry units resulting from repointing or patch repairs.
-
Terra Cotta Soiled Copper:
- TPAS Code: Cpr, AutoCAD Layer: TerraCotta_SoilStain
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Greenish copper-based stains, typically appearing as streaks below patinated copper elements.
-
Terra Cotta Soiled Guano:
- TPAS Code: Gua, AutoCAD Layer: TerraCotta_SoilStain
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Accumulation of bird droppings on the surface of masonry.
-
Terra Cotta Soiled Leached Salts:
- TPAS Code: Lch, AutoCAD Layer: TerraCotta_SoilStain
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Hard encrustations or deposits of salts on the surface of masonry, typically caused by salts being leached out of the mortar or back-up masonry through the effects of moisture.
-
Terra Cotta Soiled Paint:
- TPAS Code: Pnt, AutoCAD Layer: TerraCotta_SoilStain
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Unintended drips or accumulations on the surface of masonry units resulting from painting work.
-
Terra Cotta Soiled Rust:
- TPAS Code: Rst, AutoCAD Layer: TerraCotta_SoilStain
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Orange brown iron-based stains, typically appearing as streaks below steel or cast iron fasteners or elements.
-
Terra Cotta Spall Bonded:
- TPAS Code: B, AutoCAD Layer: TerraCotta_Spall
- Severtity Units: Not applicable, Amount Units: Size in square inches
- Description: Piece of material dislodged from a terra cotta unit by excessive stress that appears, based on visual inspection and sounding with a mallet where possible, to be solidly attached to the substrate, typically be means of mortar or adhesive.
-
Terra Cotta Spall Hazard:
- TPAS Code: Haz, AutoCAD Layer: TerraCotta_Spall
- Severtity Units: Not applicable, Amount Units: Size in square inches
- Description: Piece of material dislodged from a terra cotta unit by excessive stress that is loosely attached and presents and imminent life safety hazard, but which could not be safely removed during the investigation.
-
Terra Cotta Spall Incipient:
- TPAS Code: I, AutoCAD Layer: TerraCotta_Spall
- Severtity Units: Not applicable, Amount Units: Size in square inches
- Description: Partially formed spall that appears to be well attached.
-
Terra Cotta Spall Missing:
- TPAS Code: M, AutoCAD Layer: TerraCotta_Spall
- Severtity Units: Not applicable, Amount Units: Size in square inches
- Description: The location of a spall that is no longer in situ at the time of investigation, with no steel evident.
-
Terra Cotta Spall Missing + Steel:
- TPAS Code: MS, AutoCAD Layer: TerraCotta_Spall
- Severtity Units: Not applicable, Amount Units: Size in square inches
- Description: The location of a spall that is no longer in situ at the time of investigation and where there is steel evident, typically within the depression left by the missing spall.
-
Terra Cotta Spall Removed:
- TPAS Code: R, AutoCAD Layer: TerraCotta_Spall
- Severtity Units: Not applicable, Amount Units: Size in square inches
- Description: The location of a spall that was taken from the building at the time of the investigation, with no steel evident.
-
Terra Cotta Spall Removed + Steel:
- TPAS Code: RS, AutoCAD Layer: TerraCotta_Spall
- Severtity Units: Not applicable, Amount Units: Size in square inches
- Description: The location of a spall that was taken from the building at the time of the investigation and where there is steel evident, typically within the depression left by the missing spall.
-
Terra Cotta Surface Chipped:
- TPAS Code: Chp, AutoCAD Layer: TerraCotta_SurfLoss
- Severtity Units: Depth of loss in 1/8 inch increments, Amount Units: Area affected in square feet
- Description: Shallow loss of material, typically at the edges of the terra cotta unit.
-
Terra Cotta Surface Glaze Loss:
- TPAS Code: Glz, AutoCAD Layer: TerraCotta_SurfLoss
- Severtity Units: Depth of loss in 1/8 inch increments, Amount Units: Area affected in square feet
- Description: Loss of glaze at the surface of a terra cotta unit, either in discrete spots or wholesale disappearance of glaze, revealing the porous bisque beneath.
-
Terra Cotta Unsecured Hazardous:
- TPAS Code: Haz, AutoCAD Layer: TerraCotta_Unsecured
- Severtity Units: Not applicable, Amount Units: Area in square feet
- Description: Terra cotta unit or area that has lost its material integrity and presents a life safety hazard.
-
Terra Cotta Unsecured Hollow:
- TPAS Code: H, AutoCAD Layer: TerraCotta_Unsecured
- Severtity Units: Not applicable, Amount Units: Area in square feet
- Description: Area of terra cotta masonry that appears to have a void behind the intact surface, based on sounding with a mallet.
-
Terra Cotta Unsecured Loose:
- TPAS Code: L, AutoCAD Layer: TerraCotta_Unsecured
- Severtity Units: Not applicable, Amount Units: Area in square feet
- Description: Area of terra cotta masonry that can be moved by hand or when sounded with a mallet due to its loss of construction integrity.
-
Terra Cotta Unsecured Missing:
- TPAS Code: M, AutoCAD Layer: TerraCotta_Unsecured
- Severtity Units: Not applicable, Amount Units: Area in square feet
- Description: Area of terra cotta masonry where a void is visible at the surface due to partially or completely missing units(s).
-
Terra Cotta Unsecured Removed:
- TPAS Code: R, AutoCAD Layer: TerraCotta_Unsecured
- Severtity Units: Not applicable, Amount Units: Area in square feet
- Description: Area of terra cotta masonry where a portion or complete unit was removed at the time of investigation.
-
Concrete Lintel Pack Rust:
- TPAS Code: Pck, AutoCAD Layer: Concrete_Lintel
- Severtity Units: Not Applicable, Amount Units: Not Applicable
- Description: Expansive rusting of lintels or relieving angles constructed of rolled steel.
-
Terra Cotta Soiled Efflorescence:
- TPAS Code: Eff, AutoCAD Layer: TerraCotta_SoilStain
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: White, soft deposition on the surface of masonry due to evaporative precipitation of salts. When this process occurs below the surface of the masonry unit (subflorescence), it is revealed at areas of exfoliation or spalling.
-
Architectural Metal Coating Sound:
- TPAS Code: Ct, AutoCAD Layer: ArchMetal_Coating
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Coating that exhibits no sign of deterioration.
-
Architectural Metal Coating Failed:
- TPAS Code: CtF, AutoCAD Layer: ArchMetal_Coating
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Coating that exhibits deterioration such as blistering, peeling, wrinkling, crazing, checking, alligatoring, chalking, staining or discoloration.
-
Architectural Metal Connection Failed Fastener:
- TPAS Code: FstF, AutoCAD Layer: ArchMetal_Connection
- Severtity Units: Not applicable, Amount Units: Number of failed fasteners
- Description: Connection between architectural metal elements in which the fasteners between the elements are missing, loose, cracked or show other signs of reduced effectiveness.
-
Architectural Metal Connection Failed Flange:
- TPAS Code: FlF, AutoCAD Layer: ArchMetal_Connection
- Severtity Units: Not applicable, Amount Units: Length in lineal feet
- Description: Connection between architectural metal elements in which the flanges of the elements have cracked or show other signs of deterioration.
-
Architectural Metal Connection Failed Weld:
- TPAS Code: WldF, AutoCAD Layer: ArchMetal_Connection
- Severtity Units: Not applicable, Amount Units: Length in lineal feet
- Description: Connection between architectural metal elements in which the weld between the elements is missing, cracked or shows other signs of deterioration.
-
Architectural Metal Corrosion Fastener Rusted:
- TPAS Code: FstRst, AutoCAD Layer: ArchMetal_Corrosion
- Severtity Units: Not applicable, Amount Units: Number of corroded fasteners
- Description: Surface or pack rust at fastener.
-
Architectural Metal Corrosion Perforated:
- TPAS Code: Prf, AutoCAD Layer: ArchMetal_Corrosion
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Rusting of a metal element, which has resulted in holes or perforations in the element.
-
Architectural Metal Corrosion Pitted:
- TPAS Code: Pit, AutoCAD Layer: ArchMetal_Corrosion
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Rusting of a metal element, which has resulted in depressions or pitting in the surface of the element.
-
Architectural Metal Corrosion Surface:
- TPAS Code: Srf, AutoCAD Layer: ArchMetal_Corrosion
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Rust on the surface of a metal element, which has not yet resulted in delamination or expansion of the element.
-
Architectural Metal Crack:
- TPAS Code: C, AutoCAD Layer: ArchMetal_Crack
- Severtity Units: Width in 1/16 inch increments, Amount Units: Length in lineal feet
- Description: A crack through a metal element.
-
Architectural Metal Damage Bent:
- TPAS Code: Bnt, AutoCAD Layer: ArchMetal_Damaged
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Deformation or bend in a metal element.
-
Architectural Metal Damage Dented:
- TPAS Code: Dnt, AutoCAD Layer: ArchMetal_Damaged
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Depression or dent in a metal element.
-
Architectural Metal Sealant Failed:
- TPAS Code: SlntF, AutoCAD Layer: ArchMetal Sealant Failed
- Severtity Units: Not applicable, Amount Units: Lineal feet of sealant failed
- Description: Sealant that exhibits cracking, separation, total loss or other signs of deterioration.
-
Architectural Metal Soiled Atmospheric:
- TPAS Code: Atm, AutoCAD Layer: ArchMetal_SoilStain
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Soiling from airborne pollutants.
-
Architectural Metal Soiled Bituminous:
- TPAS Code: Bit, AutoCAD Layer: ArchMetal_SoilStain
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Surface soiling from bituminous (hydrocarbon derived from crude oil) roofing or flashing materials.
-
Architectural Metal Soiled Cementitous:
- TPAS Code: Cem, AutoCAD Layer: ArchMetal_SoilStain
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Cementitious accretions or accumulations on the surface of a metal element.
-
Architectural Metal Soiled Copper:
- TPAS Code: Cpr, AutoCAD Layer: ArchMetal_SoilStain
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Greenish copper-based stains, typically appearing as streaks below patinated copper elements.
-
Architectural Metal Soiled Guano:
- TPAS Code: Gua, AutoCAD Layer: ArchMetal_SoilStain
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Accumulation of bird droppings on the surface of a metal element.
-
Architectural Metal Soiled Paint:
- TPAS Code: Pnt, AutoCAD Layer: ArchMetal_SoilStain
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Unintended drips or accumulations on the surface of a metal element units resulting from painting work.
-
Architectural Metal Soiled Rust:
- TPAS Code: Rst, AutoCAD Layer: ArchMetal_SoilStain
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Orange brown iron-based stains, typically appearing as streaks below steel or cast iron fasteners or elements.
-
Architectural Metal Unsecured Hazard:
- TPAS Code: Haz, AutoCAD Layer: ArchMetal_Unsecured
- Severtity Units: Not applicable, Amount Units: Area in square feet
- Description: Metal element or area that has lost its material integrity and presents a life safety hazard.
-
Architectural Metal Unsecured Loose:
- TPAS Code: L, AutoCAD Layer: ArchMetal_Unsecured
- Severtity Units: Not applicable, Amount Units: Area in square feet
- Description: Metal element or area that can be moved by hand or when sounded with a mallet due to its loss of construction integrity.
-
Architectural Metal Unsecured Missing:
- TPAS Code: M, AutoCAD Layer: ArchMetal_Unsecured
- Severtity Units: Not applicable, Amount Units: Area in square feet
- Description: Metal element or area where a void is visible due to partially or completely missing element(s).
-
Architectural Metal Unsecured Removed:
- TPAS Code: R, AutoCAD Layer: ArchMetal_Unsecured
- Severtity Units: Not applicable, Amount Units: Area in square feet
- Description: Metal element or area where a portion or complete element was removed at the time of investigation.
-
Glass Bulge:
- TPAS Code: Blg, AutoCAD Layer: Glass_Displ
- Severtity Units: Not applicable, Amount Units: Not applicable
- Description: Bow inward or outward in a section of glass.
-
Glass Cracked:
- TPAS Code: C, AutoCAD Layer: Glass_Crack
- Severtity Units: Not applicable, Amount Units: Not applicable
- Description: A crack in a glass pane.
-
Glass Putty Failed:
- TPAS Code: PtyF, AutoCAD Layer: Glass_Joint
- Severtity Units: Not applicable, Amount Units: Not applicable
- Description: Putty at glass pane that exhibits cracking, separation, total loss or other signs of deterioration.
-
Glass Sealant Failed:
- TPAS Code: SlntF, AutoCAD Layer: Glass_Joint
- Severtity Units: Not applicable, Amount Units: Not applicable
- Description: Sealant that exhibits cracking, separation, total loss or other signs of deterioration.
-
Glass Soiled Bituminous:
- TPAS Code: Bit, AutoCAD Layer: Glass_SoilStain
- Severtity Units: Not applicable, Amount Units: Not applicable
- Description: Surface soiling from bituminous (hydrocarbon derived from crude oil) roofing or flashing materials.
-
Glass Soiled Cementitous:
- TPAS Code: Cem, AutoCAD Layer: Glass_SoilStain
- Severtity Units: Not applicable, Amount Units: Not applicable
- Description: Cementitious accretions or accumulations on the surface of a metal element.
-
Glass Soiled Paint:
- TPAS Code: Pnt, AutoCAD Layer: Glass_SoilStain
- Severtity Units: Not applicable, Amount Units: Not applicable
- Description: Unintended drips or accumulations on the surface of a metal element units resulting from painting work.
-
Glass Unsecured Hazardous:
- TPAS Code: Haz, AutoCAD Layer: Glass_Unsecured
- Severtity Units: Not applicable, Amount Units: Not applicable
- Description: Glass pane or fragment that has lost its material integrity and presents a life safety hazard.
-
Glass Unsecured Loose:
- TPAS Code: L, AutoCAD Layer: Glass_Unsecured
- Severtity Units: Not applicable, Amount Units: Not applicable
- Description: Glass pane or fragment that can be moved by hand or when sounded with a mallet due to its loss of construction integrity.
-
Glass Unsecured Missing:
- TPAS Code: M, AutoCAD Layer: Glass_Unsecured
- Severtity Units: Not applicable, Amount Units: Not applicable
- Description: Area where a void is visible due to partially or completely missing pane(s).
-
Glass Unsecured Removed:
- TPAS Code: R, AutoCAD Layer: Glass_Unsecured
- Severtity Units: Not applicable, Amount Units: Not applicable
- Description: Area where a portion or complete pane was removed at the time of investigation.
-
Plaster Coating Failed:
- TPAS Code: CtF, AutoCAD Layer: Plaster_Coating
- Severtity Units: Not applicable, Amount Units: Area in square feet
- Description: Coating that exhibits deterioration such as blistering, peeling, wrinkling, crazing, checking, alligatoring, chalking, staining or discoloration.
-
Plaster Coating Sound:
- TPAS Code: Ct, AutoCAD Layer: Plaster _Coating
- Severtity Units: Not applicable, Amount Units: Area in square feet
- Description: Coating that exhibits no sign of deterioration.
-
Plaster Crack:
- TPAS Code: C, AutoCAD Layer: Plaster_Crack
- Severtity Units: Crack Width in 1/16 inch increments, Amount Units: Length in lineal feet
- Description: A crack in plaster.
-
Plaster Lath Failed:
- TPAS Code: LthF, AutoCAD Layer: Plaster_Damaged
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Area where wood or metal lath is visible and exhibits signs of deterioration such as breaking, holes, or tears.
-
Plaster Repair Patch Failed:
- TPAS Code: PF, AutoCAD Layer: Plaster_Repair
- Severtity Units: Not applicable, Amount Units: Size in square inches
- Description: A previous repair to an area of plaster, typically made with cementitious material, that is cracked, separated, loose or otherwise deteriorated.
-
Plaster Repair Patch Sound:
- TPAS Code: P, AutoCAD Layer: Plaster_Repair
- Severtity Units: Not applicable, Amount Units: Size in square inches
- Description: A previous repair to an area of plaster, typically made with cementitious material, that exhibits no signs of failure.
-
Plaster Repair Replacement:
- TPAS Code: Rpl, AutoCAD Layer: Plaster_Repair
- Severtity Units: Not applicable, Amount Units: Size in square feet
- Description: A repair made to plaster in which a section of new applied-in-place plaster has been installed to replace an area of deterioration.
-
Plaster Unsecured Hazardous:
- TPAS Code: Haz, AutoCAD Layer: Plaster_Unsecured
- Severtity Units: Not applicable, Amount Units: Area in sq. ft.
- Description: Area of plaster that has lost its material integrity and presents a life safety hazard.
-
Plaster Unsecured Hollow:
- TPAS Code: H, AutoCAD Layer: Plaster_Unsecured
- Severtity Units: Not applicable, Amount Units: Area in square feet
- Description: Area of plaster that appears to have a void behind the intact surface, based on sounding with a mallet.
-
Plaster Unsecured Loose:
- TPAS Code: L, AutoCAD Layer: Plaster_Unsecured
- Severtity Units: Not applicable, Amount Units: Area in square feet
- Description: Area of plaster that can be moved by hand or when sounded with a mallet due to its loss of construction integrity.
-
Plaster Unsecured Missing:
- TPAS Code: M, AutoCAD Layer: Plaster_Unsecured
- Severtity Units: Not applicable, Amount Units: Area in square feet
- Description: Location where a void is visible at the surface due to partially or completely missing area(s).
-
Plaster Unsecured Removed:
- TPAS Code: R, AutoCAD Layer: Plaster_Unsecured
- Severtity Units: Not applicable, Amount Units: Area in square feet
- Description: Location where a portion or complete area of plaster was removed at the time of investigation.
-
Plaster Water Damage:
- TPAS Code: WDmg, AutoCAD Layer: Plaster_Damaged
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Deterioration such as erosion, friability or loss at plaster due to the effects of water.
-
Plaster Water Stain:
- TPAS Code: WStn, AutoCAD Layer: Plaster_SoilStain
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Discoloration of plaster due to the effects of water.
-
Sheet Metal Coating Failed:
- TPAS Code: CtF, AutoCAD Layer: SheetMetal_Coating
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Coating that exhibits deterioration such as blistering, peeling, wrinkling, crazing, checking, alligatoring, chalking, staining or discoloration.
-
Sheet Metal Coating Sound:
- TPAS Code: Ct, AutoCAD Layer: SheetMetal_Coating
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Coating that exhibits no sign of deterioration.
-
Sheet Metal Corrosion Fastener Rusted:
- TPAS Code: FstRst, AutoCAD Layer: SheetMetal_Corrosion
- Severtity Units: Not applicable, Amount Units: Number of corroded fasteners
- Description: Surface or pack rust at fastener.
-
Sheet Metal Corrosion Perforated:
- TPAS Code: Prf, AutoCAD Layer: SheetMetal_Corrosion
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Rusting of a metal element, which has resulted in holes or perforations in the element.
-
Sheet Metal Corrosion Pitted:
- TPAS Code: Pit, AutoCAD Layer: SheetMetal_Corrosion
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Rusting of a metal element, which has resulted in depressions or pitting in the surface of the element.
-
Sheet Metal Corrosion Surface:
- TPAS Code: Srf, AutoCAD Layer: SheetMetal_Corrosion
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Rust on the surface of a metal element, which has not yet resulted in delamination or expansion of the element.
-
Sheet Metal Damage Dented:
- TPAS Code: Dnt, AutoCAD Layer: SheetMetal_Damage
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Depression or dent in a metal element.
-
Sheet Metal Damage Punctured:
- TPAS Code: Pnc, AutoCAD Layer: Sheetmetal_Damage
- Severtity Units: Not applicable, Amount Units: Diameter in inches
- Description: Hole or puncture in a metal element.
-
Sheet Metal Damage Torn:
- TPAS Code: Trn, AutoCAD Layer: SheetMetal_Damage
- Severtity Units: Not applicable, Amount Units: Length in feet
- Description: Rip or tear in metal element.
-
Sheet Metal Repair Patch Failed:
- TPAS Code: PF, AutoCAD Layer: SheetMetal_Repair
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: A previous repair to a metal element, typically made with a new sheet metal piece material, that is cracked, separated, loose or otherwise deteriorated.
-
Sheet Metal Repair Patch Sound:
- TPAS Code: P, AutoCAD Layer: SheetMetal_Repair
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: A previous repair to a metal element, typically made with a new sheet metal piece, that exhibits no signs of failure.
-
Sheet Metal Repair Replacement:
- TPAS Code: Rpl, AutoCAD Layer: SheetMetal_Repair
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: A repair made to sheet metal in which a new sheet metal element has been installed to replace an area of deterioration.
-
Sheet Metal Sealant Failed:
- TPAS Code: SlntF, AutoCAD Layer: SheetMetal_Seam
- Severtity Units: Not applicable, Amount Units: Lineal feet of sealant
- Description: Sealant that exhibits cracking, separation, total loss or other signs of deterioration.
-
Sheet Metal Seam Failed Fasteners:
- TPAS Code: FstF, AutoCAD Layer: SheetMetal_Seam
- Severtity Units: Not applicable, Amount Units: Number of fasteners
- Description: Seam formed by mechanical fasteners between sheet metal elements that exhibits tearing, separation or other signs of deterioration.
-
Sheet Metal Seam Failed Folded:
- TPAS Code: FldF, AutoCAD Layer: SheetMetal_Seam
- Severtity Units: Not applicable, Amount Units: Length in lineal feet
- Description: Seam formed by folding sheet metal elements that exhibits tearing, separation or other signs of deterioration.
-
Sheet Metal Seam Failed Solder:
- TPAS Code: SldF, AutoCAD Layer: SheetMetal_Seam
- Severtity Units: Not applicable, Amount Units: Length in lineal feet
- Description: Seam formed by soldering between sheet metal elements that exhibits tearing, separation or other signs of deterioration.
-
Sheet Metal Soiled Atmospheric:
- TPAS Code: Atm, AutoCAD Layer: SheetMetal_SoilStain
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Soiling from airborne pollutants.
-
Sheet Metal Soiled Bituminous:
- TPAS Code: Bit, AutoCAD Layer: SheetMetal_SoilStain
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Surface soiling from bituminous (hydrocarbon derived from crude oil) roofing or flashing materials.
-
Sheet Metal Soiled Cementitous:
- TPAS Code: Cem, AutoCAD Layer: SheetMetal_SoilStain
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Cementitious accretions or accumulations on the surface of a metal element.
-
Sheet Metal Soiled Copper:
- TPAS Code: Cpr, AutoCAD Layer: SheetMetal_SoilStain
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Greenish copper-based stains, typically appearing as streaks below patinated copper elements.
-
Sheet Metal Soiled Guano:
- TPAS Code: Gua, AutoCAD Layer: SheetMetal_SoilStain
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Accumulation of bird droppings on the surface of a metal element.
-
Sheet Metal Soiled Paint:
- TPAS Code: Pnt, AutoCAD Layer: SheetMetal_SoilStain
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Unintended drips or accumulations on the surface of a metal element resulting from painting work.
-
Sheet Metal Soiled Rust:
- TPAS Code: Rst, AutoCAD Layer: SheetMetal_SoilStain
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Orange brown iron-based stains, typically appearing as streaks below steel or cast iron fasteners or elements.
-
Sheet Metal Unsecured Hazard:
- TPAS Code: Haz, AutoCAD Layer: SheetMetal_Unsecured
- Severtity Units: Not applicable, Amount Units: Area in square feet
- Description: Metal element or area that has lost its material integrity and presents a life safety hazard.
-
Sheet Metal Unsecured Loose:
- TPAS Code: L, AutoCAD Layer: SheetMetal_Unsecured
- Severtity Units: Not applicable, Amount Units: Area in square feet
- Description: Metal element or area that can be moved by hand or when sounded with a mallet due to its loss of construction integrity.
-
Sheet Metal Unsecured Missing:
- TPAS Code: M, AutoCAD Layer: SheetMetal_Unsecured
- Severtity Units: Not applicable, Amount Units: Area in sq. ft
- Description: Metal element or area where a void is visible due to partially or completely missing element(s).
-
Sheet Metal Unsecured Removed:
- TPAS Code: R, AutoCAD Layer: SheetMetal_Unsecured
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Metal element or area where a portion or complete element was removed at the time of investigation.
-
Slate Soiled Biological:
- TPAS Code: Bio, AutoCAD Layer: Slate_SoilStain
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Microbiological plant growth on the surface of the slate, such as algae, moss or lichen, or vascular plant growth, typically in gutters, cracks or on roofs.
-
Slate Soiled Bituminous:
- TPAS Code: Bit, AutoCAD Layer: Slate_SoilStain
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Surface soiling from bituminous (hydrocarbon derived from crude oil) roofing or flashing materials.
-
Slate Soiled Cementitous:
- TPAS Code: Cem, AutoCAD Layer: Slate_SoilStain
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Cementitious accretions or accumulations on the surface of the slate.
-
Slate Soiled Guano:
- TPAS Code: Gua, AutoCAD Layer: Slate_SoilStain
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Accumulation of bird droppings on the surface of the slate.
-
Slate Soiled Paint:
- TPAS Code: Pnt, AutoCAD Layer: Slate_SoilStain
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Unintended drips or accumulations on the surface of the slate resulting from painting work.
-
Slate Soiled Rust:
- TPAS Code: Rst, AutoCAD Layer: Slate_SoilStain
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Orange brown iron-based stains, typically appearing as streaks below steel or cast iron fasteners or elements.
-
Slate Cracked:
- TPAS Code: C, AutoCAD Layer: Slate_Crack
- Severtity Units: Not applicable, Amount Units: Number of slates affected
- Description: A crack in a slate unit.
-
Slate Unsecured Fastener Failed:
- TPAS Code: FstF, AutoCAD Layer: Slate_Connection
- Severtity Units: Not applicable, Amount Units: Number of slates affected
- Description: Mechanical fastener at a slate tile or area of slate that is missing or no longer intact.
-
Slate Unsecured Hazardous:
- TPAS Code: Haz, AutoCAD Layer: Slate_Unsecured
- Severtity Units: Not applicable, Amount Units: Number of slates affected
- Description: Slate tile or area of slate that has lost its material integrity and presents a life safety hazard.
-
Slate Unsecured Loose:
- TPAS Code: L, AutoCAD Layer: Slate_Unsecured
- Severtity Units: Not applicable, Amount Units: Number of slates affected
- Description: Slate tile or area of slate that can be moved by hand or when sounded with a mallet due to its loss of construction integrity.
-
Slate Unsecured Missing:
- TPAS Code: M, AutoCAD Layer: Slate_Unsecured
- Severtity Units: Not applicable, Amount Units: Number of slates affected
- Description: Slate tile or area of slate that is partially or completely missing at the time of investigation.
-
Slate Unsecured Removed:
- TPAS Code: R, AutoCAD Layer: Slate_Unsecured
- Severtity Units: Not applicable, Amount Units: Number of slate affected
- Description: Slate tile or area of slate that was removed at the time of investigation.
-
Stucco Coating Failed:
- TPAS Code: CtF, AutoCAD Layer: Stucco_Coating
- Severtity Units: Not applicable, Amount Units: Area in square feet
- Description: Coating that exhibits deterioration such as blistering, peeling, wrinkling, crazing, checking, alligatoring, chalking, staining or discoloration.
-
Stucco Coating Sound:
- TPAS Code: Ct, AutoCAD Layer: Stucco_Coating
- Severtity Units: Not applicable, Amount Units: Area in square feet
- Description: Coating that exhibits no sign of deterioration.
-
Stucco Crack:
- TPAS Code: C, AutoCAD Layer: Stucco_Crack
- Severtity Units: Crack Width in 1/16 inch increments, Amount Units: Length in lineal feet
- Description: A crack in stucco.
-
Stucco Crack Repair Sound:
- TPAS Code: CRpr, AutoCAD Layer: Stucco_Crack
- Severtity Units: Not applicable, Amount Units: Length in lineal feet
- Description: A crack or crack system that has been filled using elastomeric, cementitous or other repair material.
-
Stucco Crack Repair Failed:
- TPAS Code: CRprF, AutoCAD Layer: Stucco_Crack
- Severtity Units: Not applicable, Amount Units: Length in lineal feet
- Description: A crack or crack system that has been filled using elastomeric, cementitous or other repair material in which the repair material exhibits signs of failure or deterioration.
-
Stucco Ferrous Element:
- TPAS Code: Fe, AutoCAD Layer: Stucco_Embed
- Severtity Units: Not applicable, Amount Units: Not applicable
- Description: Steel or iron fixture embedded in stucco; examples include anchors, fasteners and pipes.
-
Stucco Repair Patch Failed:
- TPAS Code: PF, AutoCAD Layer: Stucco Rpr Patch Failed
- Severtity Units: Not applicable, Amount Units: Size in square inches
- Description: A previous repair to an area of stucco, typically made with cementitious material, that is cracked, separated, loose or otherwise deteriorated.
-
Stucco Repair Patch Sound:
- TPAS Code: P, AutoCAD Layer: Stucco_Repair
- Severtity Units: Not applicable, Amount Units: Size in square inches
- Description: A previous repair to an area of stucco, typically made with cementitious material, that exhibits no signs of failure.
-
Stucco Sealant Failed:
- TPAS Code: SlntF, AutoCAD Layer: Stucco_Joint
- Severtity Units: Not applicable, Amount Units: Lineal feet of sealant failed
- Description: Sealant that exhibits cracking, separation, total loss or other signs of deterioration.
-
Stucco Soiled Atmospheric:
- TPAS Code: Atm, AutoCAD Layer: Stucco_SoilStain
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Soiling from airborne pollutants.
-
Stucco Soiled Biological:
- TPAS Code: Bio, AutoCAD Layer: Stucco_SoilStain
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Microbiological plant growth on the surface of the stucco, such as algae, moss or lichen, or vascular plant growth, typically in gutters, cracks or on roofs.
-
Stucco Soiled Bituminous:
- TPAS Code: Bit, AutoCAD Layer: Stucco_SoilStain
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Surface soiling from bituminous (hydrocarbon derived from crude oil) roofing or flashing materials.
-
Stucco Soiled Copper:
- TPAS Code: Cpr, AutoCAD Layer: Stucco_SoilStain
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Greenish copper-based stains, typically appearing as streaks below patinated copper elements.
-
Stucco Soiled Guano:
- TPAS Code: Gua, AutoCAD Layer: Stucco_SoilStain
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Accumulation of bird droppings on the surface of stucco.
-
Stucco Soiled Paint:
- TPAS Code: Pnt, AutoCAD Layer: Stucco_SoilStain
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Unintended drips or accumulations on the surface of the stucco resulting from painting work.
-
Stucco Soiled Rust:
- TPAS Code: Rst, AutoCAD Layer: Stucco_SoilStain
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Orange brown iron-based stains, typically appearing as streaks below steel or cast iron fasteners or elements.
-
Stucco Unsecured Hazardous:
- TPAS Code: Haz, AutoCAD Layer: Stucco_Unsecured
- Severtity Units: Not applicable, Amount Units: Area in square feet
- Description: Area of stucco that has lost its material integrity and presents a life safety hazard.
-
Stucco Unsecured Hollow:
- TPAS Code: H, AutoCAD Layer: Stucco_Unsecured
- Severtity Units: Not applicable, Amount Units: Area in square feet
- Description: Area of stucco that appears to have a void behind the intact surface, based on sounding with a mallet.
-
Stucco Unsecured Loose:
- TPAS Code: L, AutoCAD Layer: Stucco_Unsecured
- Severtity Units: Not applicable, Amount Units: Area in square feet
- Description: Area of stucco that can be moved by hand or when sounded with a mallet due to its loss of construction integrity.
-
Stucco Unsecured Missing:
- TPAS Code: M, AutoCAD Layer: Stucco_Unsecured
- Severtity Units: Not applicable, Amount Units: Area in square feet
- Description: Location where a void is visible at the surface due to partially or completely missing area(s).
-
Stucco Unsecured Removed:
- TPAS Code: R, AutoCAD Layer: Stucco_Unsecured
- Severtity Units: Not applicable, Amount Units: Area in square feet
- Description: Location where a portion or complete area of stucco was removed at the time of investigation.
-
Wood Abraded:
- TPAS Code: Abr, AutoCAD Layer: Wood_Deteriorated
- Severtity Units: Depth in 1/8” increments, Amount Units: Area affected in square feet
- Description: Wear on the surface of wood from wind-blown dusts, water or hardware.
-
Wood Biological Growth Fungi:
- TPAS Code: Fng, AutoCAD Layer: Wood_Bio_Growth
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Decay-causing plant growth at wood, such as fungi or mold.
-
Wood Biological Growth Plants Higher:
- TPAS Code: PlntHi, AutoCAD Layer: Wood_Bio_Growth
- Severtity Units: Not applicable, Amount Units: Not applicable
- Description: Vascular plant growth at wood.
-
Wood Biological Growth Plants Lower:
- TPAS Code: PlntLo, AutoCAD Layer: Wood_Bio_Growth
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Microbiological plant growth at wood, such as algae, moss or lichen.
-
Wood Checked:
- TPAS Code: Chk, AutoCAD Layer: Wood_Crack
- Severtity Units: Width in 1/16 inch increments, Amount Units: Length in lineal feet
- Description: A split in wood lengthwise across the growth rings, caused by uneven shrinkage during drying.
-
Wood Coating Failed:
- TPAS Code: CtF, AutoCAD Layer: Wood_Coating
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Coating that exhibits deterioration such as blistering, peeling, wrinkling, crazing, checking, alligatoring, chalking, staining or discoloration.
-
Wood Crack:
- TPAS Code: C, AutoCAD Layer: Wood_Crack
- Severtity Units: Width in 1/16 inch increments, Amount Units: Length in lineal feet
- Description: A crack in wood.
-
Wood Damage Infested Insect:
- TPAS Code: Ins, AutoCAD Layer: Wood_Damage_Infested
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Deterioration caused by insects, such as beetles, termites, ants or bees.
-
Wood Damage Infested Mammal:
- TPAS Code: Mam, AutoCAD Layer: Wood_Damage_Infested
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Deterioration caused by mammals, such as squirrels or mice.
-
Wood Repair Dutchman Failed:
- TPAS Code: DF, AutoCAD Layer: Wood_Repair
- Severtity Units: Not applicable, Amount Units: Size in square inches
- Description: A previous repair to a wood element unit, made by installing a natural wood infill piece at an area of deterioration, that is cracked, separated, loose or otherwise failing.
-
Wood Repair Dutchman Sound:
- TPAS Code: D, AutoCAD Layer: Wood_Repair
- Severtity Units: Not applicable, Amount Units: Size in square inches
- Description: A previous repair to a wood element unit, made by installing a natural wood infill piece at an area of deterioration, that exhibits no sign of failure.
-
Wood Repair Patch Failed:
- TPAS Code: PF, AutoCAD Layer: Wood_Repair
- Severtity Units: Not applicable, Amount Units: Size in square inches
- Description: A previous repair to an area of wood, typically made with epoxy-based material, that is cracked, separated, loose or otherwise deteriorated.
-
Wood Repair Patch Sound:
- TPAS Code: P, AutoCAD Layer: Wood_Repair
- Severtity Units: Not applicable, Amount Units: Size in square inches
- Description: A previous repair to an area of wood, typically made with epoxy-based material.
-
Wood Repair Replacement:
- TPAS Code: Rpl, AutoCAD Layer: Wood_Repair
- Severtity Units: Not applicable, Amount Units: Number of replacement units
- Description: A repair made to wood in which a new wood element has been installed to replace an area of deterioration.
-
Wood Rotten:
- TPAS Code: Rot, AutoCAD Layer: Wood_Deteriorated
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Area of softness or loss due to fungal attack.
-
Wood Sealant Failed:
- TPAS Code: SlntF, AutoCAD Layer: Wood_Joint
- Severtity Units: Not applicable, Amount Units: Area in square feet
- Description: Sealant that exhibits cracking, separation, total loss or other signs of deterioration.
-
Wood Soiled Bituminous:
- TPAS Code: Bit, AutoCAD Layer: Wood_SoilStain
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Surface soiling from bituminous (hydrocarbon derived from crude oil) roofing or flashing materials.
-
Wood Soiled Cementitous:
- TPAS Code: Cem, AutoCAD Layer: Wood_SoilStain
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Cementitious accretions or accumulations on the surface of the wood.
-
Wood Soiled Guano:
- TPAS Code: Gua, AutoCAD Layer: Wood_SoilStain
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Accumulation of bird droppings on the surface of the stucco.
-
Wood Soiled Paint:
- TPAS Code: Pnt, AutoCAD Layer: Wood_SoilStain
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Unintended drips or accumulations on the surface of the wood resulting from painting work.
-
Wood Soiled Rust:
- TPAS Code: Rst, AutoCAD Layer: Wood_SoilStain
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Orange brown iron-based stains, typically appearing as streaks below steel or cast iron fasteners or elements.
-
Wood Unsecured Fastener Failed:
- TPAS Code: FstF, AutoCAD Layer: Wood_Unsecured
- Severtity Units: Not applicable, Amount Units: Number of fasteners failed
- Description: Mechanical fastener that is loose or no longer intact.
-
Wood Unsecured Hazardous:
- TPAS Code: Haz, AutoCAD Layer: Wood_Unsecured
- Severtity Units: Not applicable, Amount Units: Area in square feet
- Description: Wood element or area of wood that has lost its material integrity and presents a life safety hazard.
-
Wood Unsecured Loose:
- TPAS Code: L, AutoCAD Layer: Wood_Unsecured
- Severtity Units: Not applicable, Amount Units: Area in square feet
- Description: Wood element or area of wood that can be moved by hand or when sounded with a mallet due to its loss of construction integrity.
-
Wood Unsecured Missing:
- TPAS Code: M, AutoCAD Layer: Wood_Unsecured
- Severtity Units: Not applicable, Amount Units: Area in square feet
- Description: Wood element or area of wood that is partially or completely missing at the time of investigation.
-
Wood Unsecured Removed:
- TPAS Code: R, AutoCAD Layer: Wood_Unsecured
- Severtity Units: Not applicable, Amount Units: Area in square feet
- Description: Wood element or area of wood that was removed at the time of investigation.
-
Wood Weathered:
- TPAS Code: Wthr, AutoCAD Layer: Wood_Deteriorated
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Loss of softwood due to abrasion or erosion and resulting in uneven surface texture of wood.
-
Brick Joint Mortar Caulked Failed:
- TPAS Code: MorClkF, AutoCAD Layer: Brick_Joint
- Severtity Units: Not Applicable, Amount Units: Not Applicable
- Description: Joints in brick masonry where sealant has been applied over the mortar, and the sealant exhibits cracking, separation, total loss or other signs of deterioration.
-
Concrete Joints Mortar Removed:
- TPAS Code: MorR, AutoCAD Layer: Concrete_Joint
- Severtity Units: Not Applicable, Amount Units: Length in lineal feet
- Description: Failed mortar in concrete or cast stone masonry which was removed at the time of the investigation.
-
Architectural Metal Crack Repair Sound:
- TPAS Code: CRpr, AutoCAD Layer: ArchMetal_Crack
- Severtity Units: Not applicable, Amount Units: Length in lineal feet
- Description: A crack or crack system that has been filled using elastomeric, cementitous or other repair material.
-
Architectural Metal Crack Repair Failed:
- TPAS Code: CRprF, AutoCAD Layer: ArchMetal_Crack
- Severtity Units: Not applicable, Amount Units: Length in lineal feet
- Description: A crack or crack system that has been filled using elastomeric, cementitous or other repair material in which the repair material exhibits signs of failure or deterioration.
-
Architectural Metal Unsecured Hollow:
- TPAS Code: H, AutoCAD Layer: ArchMetal_Unsecured
- Severtity Units: Not applicable, Amount Units: Area in square feet
- Description: Area of architectural metal that appears to have a void behind the intact surface, based on sounding with a mallet.
-
Brick Crack Repair Removed:
- TPAS Code: CRprR, AutoCAD Layer: Brick_Crack
- Severtity Units: Not applicable, Amount Units: Length in lineal feet
- Description: A crack or crack system that has been filled using elastomeric, cementitious or other repair material, and where the failed repair material was removed at the time of the investigation.
-
Brick Repair Dutchman Sound:
- TPAS Code: D, AutoCAD Layer: Brick_Repair
- Severtity Units: Not applicable, Amount Units: Not applicable
- Description: A previous repair to a brick unit, made by installing a brick infill piece at an area of deterioration, that exhibits no sign of failure.
-
Brick Repair Dutchman Failed:
- TPAS Code: DF, AutoCAD Layer: Brick_Repair
- Severtity Units: Not applicable, Amount Units: Not applicable
- Description: A previous repair to a brick unit, made by installing a brick infill piece at an area of deterioration, that is cracked, separated, loose or otherwise failing.
-
Brick Repair Dutchman Removed:
- TPAS Code: DR, AutoCAD Layer: Brick_Repair
- Severtity Units: Not applicable, Amount Units: Not applicable
- Description: A previous repair to a brick unit, made by installing a brick infill piece at an area of deterioration, that was cracked, separated, loose or otherwise failing and was removed during the investigation.
-
Brick Soiled Black Crusts:
- TPAS Code: Blck, AutoCAD Layer: Brick_SoilStain
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Accumulation of insoluble gypsum formed by the reaction of particulate pollutants with the stone and darkened by atmospheric soiling.
-
Concrete Crack Repair Removed:
- TPAS Code: CRprR, AutoCAD Layer: Concrete_Crack
- Severtity Units: Not applicable, Amount Units: Length in lineal feet
- Description: A crack or crack system that has been filled using elastomeric, cementitious or other repair material, and where the failed repair material was removed at the time of the investigation.
-
Concrete Joint Mortar Caulked Failed:
- TPAS Code: MorClkF, AutoCAD Layer: Concrete_Joint
- Severtity Units: Not applicable, Amount Units: Length in lineal feet
- Description: Joints in concrete or cast stone masonry where sealant has been applied over the mortar, and the sealant exhibits cracking, separation, total loss or other signs of deterioration.
-
Concrete Soiled Black Crusts:
- TPAS Code: Blck, AutoCAD Layer: Concrete_SoilStain
- Severtity Units: Not applicable, Amount Units: Area affected in square feet
- Description: Accumulation of insoluble gypsum formed by the reaction of particulate pollutants with the stone and darkened by atmospheric soiling.
-
Plaster Crack Repair Sound:
- TPAS Code: CRpr, AutoCAD Layer: Plaster_Crack
- Severtity Units: Not applicable, Amount Units: Length in lineal feet
- Description: A crack or crack system that has been filled using elastomeric, cementitious or other repair material.
-
Plaster Crack Repair Failed:
- TPAS Code: CRprF, AutoCAD Layer: Plaster_Crack
- Severtity Units: Not applicable, Amount Units: Length in lineal feet
- Description: A crack or crack system that has been filled using elastomeric, cementitious or other repair material in which the repair material exhibits signs of failure or deterioration.
-
Plaster Crack Repair Removed:
- TPAS Code: CRprR, AutoCAD Layer: Plaster_Crack
- Severtity Units: Not applicable, Amount Units: Length in lineal feet
- Description: A crack or crack system that has been filled using elastomeric, cementitious or other repair material in which the repair material exhibits signs of failure or deterioration, and is removed during the investigation.
-
Plaster Repair Patch Removed:
- TPAS Code: PR, AutoCAD Layer: Plaster_Repair
- Severtity Units: Not applicable, Amount Units: Not applicable
- Description: A previous repair to an area of plaster, typically made with cementitious material, that is cracked, separated, loose or otherwise deteriorated, and is removed during the investigation.
-
Sheet Metal Repair Patch Removed:
- TPAS Code: PR, AutoCAD Layer: SheetMetal_Repair
- Severtity Units: Not applicable, Amount Units: Area in square feet
- Description: A previous repair to a metal element, typically made with a new sheet metal piece material, that is cracked, separated, loose or otherwise deteriorated, and is removed during the investigation.
-
Stucco Crack Repair Removed:
- TPAS Code: CRprR, AutoCAD Layer: Stucco_Crack
- Severtity Units: Not applicable, Amount Units: Length in lineal feet
- Description: A crack or crack system that has been filled using elastomeric, cementitious or other repair material, and where the failed repair material was removed at the time of the investigation.
-
Stucco Repair Replacement:
- TPAS Code: Rpl, AutoCAD Layer: Stucco_Repair
- Severtity Units: Not applicable, Amount Units: Area in square feet
- Description: A repair made to stucco in which new stucco has been installed to replace an area of deterioration.
-
Wood Coating Sound:
- TPAS Code: Ct, AutoCAD Layer: Wood_Coating
- Severtity Units: Not applicable, Amount Units: Area in square feet
- Description: Coating on wood that exhibits no signs of deterioration.
-
Wood Repair Dutchman Removed:
- TPAS Code: DR, AutoCAD Layer: Wood_Repair
- Severtity Units: Not applicable, Amount Units: Not applicable
- Description: A previous repair to wood, made by installing a wood infill piece at an area of deterioration, that was cracked, separated, loose or otherwise failing and was removed during the investigation.
-
Wood Patch Removed:
- TPAS Code: PR, AutoCAD Layer: Wood_Repair
- Severtity Units: Not applicable, Amount Units: Not applicable
- Description: A previous repair to an area of wood, typically made with epoxy-based material, that is cracked, separated, loose or otherwise deteriorated, and is removed during the investigation.
-
Wood Unsecured Hollow:
- TPAS Code: H, AutoCAD Layer: Wood_Unsecured
- Severtity Units: Not applicable, Amount Units: Area in square feet
- Description: Area of wood that appears to have a void behind the intact surface, based on sounding with a mallet.
-
Brick Joints Mortar Removed:
- TPAS Code: MorR, AutoCAD Layer: Brick_Joints
- Severtity Units: Not applicable, Amount Units: Length in lineal feet
- Description: Joints that exhibit eroded, friable, cracked or otherwise deteriorated mortar which is removed during the investigation.
-
Brick Repair Patch Removed:
- TPAS Code: PR, AutoCAD Layer: Brick_Repair
- Severtity Units: Not applicable, Amount Units: Not applicable
- Description: A previous repair to a brick unit, typically made with cementitious material, that is cracked, separated, loose or otherwise deteriorated, and is removed during the investigation.
-
Concrete Repair Patch Removed:
- TPAS Code: PR, AutoCAD Layer: Concrete_Repair
- Severtity Units: Not applicable, Amount Units: Not applicable
- Description: A previous repair to concrete or cast stone, typically made with cementitious material, that is cracked, separated, loose or otherwise deteriorated, and is removed during the investigation.
-
Terra Cotta Repair Patch Removed:
- TPAS Code: PR, AutoCAD Layer: TerraCotta_Repair
- Severtity Units: Not applicable, Amount Units: Not applicable
- Description: A previous repair to an area of terra cotta, typically made with cementitious material, that is cracked, separated, loose or otherwise deteriorated, and is removed during the investigation.
-
Concrete Lintel Surface Rust:
- TPAS Code: Srf, AutoCAD Layer: Concrete_Lintel
- Severtity Units: Not applicable, Amount Units: Not applicable
- Description: Rusting steel lintel or relieving angle, which has not yet begun to delaminate or expand.
-
Stone Crack Repair Removed:
- TPAS Code: CRprR, AutoCAD Layer: Stone_Crack
- Severtity Units: Not applicable, Amount Units: Length in lineal feet
- Description: A crack or crack system that has been filled using elastomeric, cementitious or other repair material, and where the failed repair material was removed at the time of the investigation.
-
Stone Joints Mortar Caulked Failed:
- TPAS Code: MorClkF, AutoCAD Layer: Stone_Joint
- Severtity Units: Not applicable, Amount Units: Not applicable
- Description: Joints in stone masonry where sealant has been applied over the mortar, and the sealant exhibits cracking, separation, total loss or other signs of deterioration.
-
Stone Joints Mortar Removed:
- TPAS Code: MorR, AutoCAD Layer: Stone_Joint
- Severtity Units: Not applicable, Amount Units: Length in lineal feet
- Description: Failed mortar in stone masonry which was removed at the time of the investigation.
-
Stone Repair Dutchman Removed:
- TPAS Code: DR, AutoCAD Layer: Stone_Repair
- Severtity Units: Not applicable, Amount Units: Not applicable
- Description: A previous repair to a stone unit, made by installing a natural stone infill piece at an area of deterioration, that was cracked, separated, loose or otherwise failing and was removed during the investigation.
-
Stone Repair Patch Removed:
- TPAS Code: PR, AutoCAD Layer: Stone_Repair
- Severtity Units: Not applicable, Amount Units: Not applicable
- Description: A previous repair to a stone unit, typically made with cementitious material, that is cracked, separated, loose or otherwise deteriorated, and is removed during the investigation.
-
Terra Cotta Crack Repair Removed:
- TPAS Code: CRprR, AutoCAD Layer: TerraCotta_Crack
- Severtity Units: Not applicable, Amount Units: Length in lineal feet
- Description: A crack or crack system that has been filled using elastomeric, cementitious or other repair material, and where the failed repair material was removed at the time of the investigation.
-
Terra Cotta Joints Mortar Caulked Failed:
- TPAS Code: MorClkF, AutoCAD Layer: TerraCotta_Joint
- Severtity Units: Not applicable, Amount Units: Not applicable
- Description: Joints in terra cotta masonry where sealant has been applied over the mortar, and the sealant exhibits cracking, separation, total loss or other signs of deterioration.